ARALDITE APPLICATIONS
SWITCHES
Switches are electromechanical devices used to
make and break, or select, an electrical circuit by manual or mechanical
operation
• Araldite CY 8770/Hardener HY 8770
• Araldite CW 8771 /Hardener HW 8771
• Araldite CW 8772/Hardener HW 8772
• Araldite CW 2243L US/Hardener HY 2966 US
• Araldite CY 221 /Hardener HY 956 EN/US
MODULES
Central units taking up and processing
electrical signals from sensors. Signals may be transformed into appropriate
physical quantities by steering switches and valves.
• Araldite CY 8770/Hardener HY 8770
• Araldite CW 8771 /Hardener HW 8771
• Araldite CW 8772/Hardener HW 8772
• Arathane CY 8780/Hardener HY 8780
• Arathane CW 8690/Hardener HW 8691
• Araldite D US/Hardener HY 956 EN/US Good for Small Modules
• Araldite CY 221 /Hardener HY 956 EN/US
• Araldite CW 2243L US/Hardener HY 2966 US
Sensors
Devices that transforms physical quantities such as
pressure, temperature, airflow and velocity into electrical signals.
• Araldite CY 8770/Hardener HY 8770
• Araldite CW 8771 /Hardener HW 8771
• Araldite CW 8772/Hardener HW 8772
• Araldite CW 8773/Hardener HW 8773
• Arathane CW 8690/Hardener 8691
Filters
Wave-shaping circuits.
• Araldite CY 8770/Hardener HY 8770
• Araldite CW 8771 /Hardener HW 8771
• Araldite CW 8772/Hardener HW 8772
• Arathane CY 8781 /Hardener HW 8781
• Arathane CY 8782/Hardener HW 8782
• Arathane CY 8783/Hardener HW 8783
• Araldite D US/Hardener HY 956 EN/US
• Araldite CW. 2122-1 /Hardener HY 2901 -1
Capacitors
Capacitors consist of conductors separated by a
dielectric for introducing capacitance into an electric circuit or system or for
providing for the storage of electric charge.
• Araldite CY 8770/Hardener HY 8770
• Araldite CW 8771 /Hardener HW 8771
• Araldite CW 8772/Hardener HW 8772
• Arathane CY 8781 /Hardener HW 8781
• Arathane CY 8782/Hardener HW 8782
• Arathane CY 8783/Hardener HW 8783
• Araldite D US/Hardener HY 956 EN/US
• Araldite CW 1277 US/Hardener HY 1277 US
• Araldite CW 1280 US/Hardener HY 1280 US
• Araldite CW 2243L US/Hardener HY 2966 US
Transformers-Step up or step down voltage.
• Araldite CW 8772/Hardener
HW 8772
• Araldite CW 8773/Hardener HW 8773
• Arathane CY 8781 /Hardener HW 8781
• Arathane CY 8782/Hardener HW 8782
• Arathane CY 8783/Hardener HW 8783
• Araldite CW 2243L US/Hardener HY 2966 US
High Voltage Transformers Step up or step down high
voltage.
Araldite CW 1277 US/Hardener HY 1277
Araldite CW 1280 US/Hardener HY 1280
Araldite CW 5702/Hardener HY 5703
Araldite CW 8762/Hardener HY 8762
Fly-Back Transformers
Used in television sets to step the voltage for the
CRT up to 2030kV.
Araldite CW 1277 US/Hardener HY 1277 US
Araldite CW 1280 US/Hardener HY 1280 US
Transformer Core Bonding
Araldite CV 5745 US
Resistors
Resistors are devices, the primary purpose of which is
to intr resistance into an electric circuit or system. The ideal resistor
dissipates electric energy without storing electric or magnet energy.
• Araldite CW 8772/Hardener HW 8772
• Araldite CW 8773/Hardener HW 8773
• Araldite CW 2243L US/Hardener HY 2966 US
• Araldite CW 2122-1 /Hardener HY 2901 -1 Focus Resistors
Voltage Regulators
Circuits designed to keep voltage within a specified
range.
Araldite CW 8772/Hardener HW 8772
Araldite CW 8773/Hardener HW 8773
Pressure Sensitive Devices
Almost always mechanical, these are elastic members
which deflect when the pressure on one side of their wall is not balanced by a
pressure on the opposite side.
• Arathane CY 8780/Hardener HW 8780
• Arathane CY 8781 /Hardener HW 8781
• Arathane CY 8782/Hardener HW 8782
• Arathane CY 8783/Hardener HW 8783
• Araldite CW 2122-1 /Hardener HY 2901 -1
Potentiometers
Measurement circuits used to evaluate level of
current.
Arathane CY 8780/Hardener 8780
BACK
|